Ready Mix Concrete · Goa

Ready Mix Concrete Supplier in Goa

Ready Mix Concrete supplied across Goa in grades from M20 through M45, with high-strength grades such as M60 available on request — mix requirements and delivery coordinated to the project, produced at RMC batching plants operated by Sabsol Qualitech Industries LLP.

Ready Mix Concrete supplied by OM Group in Goa
Product
Ready Mix Concrete (RMC)
Brand
OM Group
Production
RMC batching plants at Kundaim and Thivim, operated by Sabsol Qualitech Industries LLP
Grades
M20 to M45 supplied as standard; high-strength grades such as M60 on request — confirmed against current availability
Primary standard
IS 4926:2003 — production and supply
Mix proportioning reference
IS 10262:2019
Concrete code reference
IS 456:2000
Supply area
North Goa and South Goa
Delivery
Transit mixer
Specification
Project-specific
Documentation
Delivery ticket and available documentation as applicable

Ready Mix Concrete is specified by grade because the grade sets the structural strength the design relies on. OM Group supplies Ready Mix Concrete across North and South Goa, produced at RMC batching plants at Kundaim and Thivim operated by Sabsol Qualitech Industries LLP, with fresh concrete transported and delivered to site by transit mixer against the project's mix requirement and pour schedule.

What Is Ready Mix Concrete?

Ready Mix Concrete (RMC) is concrete produced under controlled batching and mixing conditions and supplied to a construction site in a fresh state for placement.

RMC is not simply concrete delivered by truck — it is a controlled production and supply system. Raw materials are stored and proportioned at a batching plant to a specified mix design, mixed under quality control, then transported and delivered ready for placement, with consistency managed at the point of production rather than assembled on site.

The abbreviation RMC is used interchangeably with Ready Mix Concrete in Indian construction trade usage. IS 4926:2003, the Indian Standard governing RMC production and supply, sets out batching, mixing, quality control and delivery-documentation requirements for the plant-and-transport side of the process — it does not cover placement, compaction, curing or protection after delivery, which remain the contractor's responsibility on site.

RMC vs Site-Mixed Concrete

Two ways to arrive at the same grade.

RMC and site-mixed concrete can both meet the same specified grade — the difference is in how consistently that grade is met batch to batch, and what it takes on site to get there.

 RMCSite-mixed concrete
BatchingControlled, plant-basedManual or small-mixer, on site
Material consistencyBatch-to-batch controlled at the plantVaries with site practice and crew
Labour requirementLower on-site labour for mixingHigher — mixing is a site activity
Site spaceLess storage needed on siteRequires material stockpiling space
Production scaleSuited to larger or continuous poursSuited to small quantities
SchedulingCoordinated delivery to the pour scheduleFlexible, but consistency depends on the crew
DocumentationDelivery ticket, batch recordDepends on the project's own QA system

RMC can offer advantages where controlled batching, consistency and coordinated delivery matter — it is not automatically the better choice for every project scale.

How RMC Is Produced

Production and supply, through to discharge.

Ready Mix Concrete supplied by OM Group is produced at RMC batching plants at Kundaim and Thivim operated by Sabsol Qualitech Industries LLP. The sequence below covers what happens from raw material through to discharge on site.

01Raw Materials
02Storage
03Batching
04Proportioning to Mix Design
05Mixing
06Quality Checks
07Transit Mixer Loading
08Site Delivery
09Discharge
10Placement (site contractor)

Steps 1–9 sit within RMC production and supply, governed by IS 4926:2003. Placement, compaction, finishing, curing and protection after discharge are site-side activities carried out by the project's own contractor, outside IS 4926's production-and-supply scope and outside OM Group's delivery responsibility unless separately agreed.

RMC Materials

What goes into the mix, and what each does.

Cementitious materials

Cement and, where used, supplementary cementitious materials — the primary binder driving strength development and setting behaviour.

Fine aggregate

Sand or manufactured sand, filling the space between coarse particles and affecting workability, cohesion and finish.

Coarse aggregate

Crushed stone carrying the bulk of the mix by volume, with grading affecting workability, packing and finished surface.

Water

Hydrates the cement and contributes to workability — the water-cementitious ratio is a primary driver of strength and durability.

Chemical admixtures

Used where the mix design calls for them, to modify setting time, workability or durability characteristics for the specific requirement.

Mix design

Proportions each of the above against the project's strength, workability and durability requirement — not a fixed recipe applied uniformly.

No proprietary mix ratio is published on this page. Proportions are project-specific, set by the mix design against IS 10262:2019 — publishing a generic recipe without a project-specific basis would be inaccurate rather than merely unhelpful.

How Ready Mix Concrete Mix Design Works

The grade is the target; the mix design gets you there.

Mix design balances characteristic strength, target mean strength, water-cementitious ratio, workability, aggregate grading, cementitious content, admixture use, durability requirement and exposure condition against the project's actual specification, referenced against IS 10262:2019. It is not a calculator this page can substitute for — the requirement should come from the project's structural design.

Grade Selector

What RMC grade are you looking for?

M20 through M45 are supplied as standard. High-strength grades such as M60 are supplied on request, subject to project-specific mix design and confirmation. Select a grade to jump to its section.

M2020 MPa
Ordinary concrete Nominal or design mix

Commonly considered for residential RCC, slabs, beams, columns and foundations.

M2525 MPa
Standard concrete Design mix

Commonly considered where a higher durability or load requirement than M20 applies.

M3030 MPa
Standard concrete Design mix

Commonly considered for commercial construction, structural RCC and infrastructure work.

M3535 MPa
Standard concrete Design mix

Commonly considered for higher-strength structural applications in commercial and infrastructure work.

M4040 MPa
Standard concrete Design mix

Commonly considered for high-demand structural applications across infrastructure and industrial work.

M4545 MPa
Standard concrete Design mix

Toward the upper end of the standard-concrete range — considered for demanding commercial or industrial structures.

M6060 MPa
High-strength concrete Design mix, performance-evaluated On Request

Specialised high-strength applications, subject to project confirmation and performance-based mix evaluation.

Grade Comparison

Side by side, at a glance.

GradeCharacteristic strengthClassificationMix typeTypical context*Availability
M2020 MPaOrdinaryNominal or design mixResidential RCC, slabs, beams, columns, foundationsStandard
M2525 MPaStandardDesign mixStructural RCC, higher-durability requirementsStandard
M3030 MPaStandardDesign mixCommercial construction, infrastructure, foundationsStandard
M3535 MPaStandardDesign mixHigher-strength structural, commercial, infrastructureStandard
M4040 MPaStandardDesign mixHigh-demand structural, infrastructure, industrialStandard
M4545 MPaStandard (upper range)Design mixDemanding commercial/industrial structuresStandard
M6060 MPaHigh-strengthDesign mix, performance-evaluatedSpecialised high-strength applicationsOn request

*Commonly considered for — not a prescription. Actual grade selection is subject to structural design and project specification.

Grade Details

Every grade, on its own terms.

M20OrdinaryNominal or design mix

M20 Ready Mix Concrete

M20 denotes a concrete grade with a characteristic cube compressive strength of 20 MPa at 28 days. It is classed as ordinary concrete under IS 456:2000, where nominal mix is permitted, though a project may still specify design mix at this grade. It is commonly considered for residential RCC, slabs, beams, columns and foundations. When ordering, confirm whether your specification calls for design mix even though nominal mix is permitted, and share quantity, pour date and delivery location for standard transit-mixer delivery.

Actual grade selection is subject to structural design and project specification.

M20 Ready Mix Concrete
M20 · 20 MPa
M25StandardDesign mix

M25 Ready Mix Concrete

M25 has a characteristic cube compressive strength of 25 MPa, in the standard-concrete category, where design mix is mandatory under IS 456:2000. It is commonly considered where a higher durability or load requirement than M20 applies. Two projects both specifying M25 can carry different water-cementitious ratio requirements depending on exposure condition — confirm exposure class alongside the strength grade when ordering, not the grade number alone.

Actual grade selection is subject to structural design and project specification.

M25 Ready Mix Concrete
M25 · 25 MPa
M30StandardDesign mix

M30 Ready Mix Concrete

M30 has a characteristic cube compressive strength of 30 MPa. It is commonly considered for structural RCC, commercial construction, slabs, beams, columns, foundations and infrastructure work. If the pour requires pump placement, raise it early — pumping affects the workability the mix design needs to deliver, and it is easier to confirm before batching than after the mixer arrives.

Actual grade selection is subject to structural design and project specification.

M30 Ready Mix Concrete
M30 · 30 MPa
M35StandardDesign mix

M35 Ready Mix Concrete

M35 has a characteristic cube compressive strength of 35 MPa. It is commonly considered for higher-strength structural applications in commercial and infrastructure work, including columns and industrial floors carrying heavier loads than M25–M30 members. At this grade, confirm the specific durability or load data your engineer has specified rather than assuming a standard specification applies uniformly.

Actual grade selection is subject to structural design and project specification.

M35 Ready Mix Concrete
M35 · 35 MPa
M40StandardDesign mix

M40 Ready Mix Concrete

M40 has a characteristic cube compressive strength of 40 MPa. It is commonly considered for high-demand structural applications across infrastructure, commercial and industrial work. A higher grade number is not itself a marketing claim — suitability is determined by the structural requirement, not by picking the highest available number. Larger or continuous pours at this grade benefit from confirming discharge sequencing and site access ahead of delivery.

Actual grade selection is subject to structural design and project specification.

M40 Ready Mix Concrete
M40 · 40 MPa
M45StandardDesign mix

M45 Ready Mix Concrete

M45 has a characteristic cube compressive strength of 45 MPa, toward the upper end of the standard-concrete range rather than the high-strength category, which begins at M60. It is commonly considered for demanding commercial or industrial structures and special RCC work. Specification at this grade tends to be more rigorous — confirm target mean strength and sampling/testing frequency directly with your requirement rather than assuming a lighter-grade procurement process applies.

Actual grade selection is subject to structural design and project specification.

M45 Ready Mix Concrete
M45 · 45 MPa
M60High-StrengthOn Request

M60 High-Strength Ready Mix Concrete

M60 denotes a characteristic cube compressive strength of 60 MPa at 28 days, the entry point into the high-strength concrete category. Above M55, IS 456's standard design tables may not directly apply — higher-strength concrete requires experimental data and performance-based mix evaluation specific to the project rather than the standard tables used for ordinary and standard grades. M60 is commonly considered for specialised high-strength and precast applications, and is supplied on request rather than as a routine stock grade.

This is a materially different procurement conversation than ordering M20–M45 — discuss your requirement directly rather than assuming standard-grade procurement timelines or documentation apply.

M60 High-Strength Ready Mix Concrete
M60 · 60 MPa
Which Grade Should I Choose?

Follow the structural design.

The correct RMC grade is determined by the structural design and project specification, not simply by choosing the highest available grade. Structural engineers set the requirement based on design loads, exposure conditions, durability needs, member type and construction method. This page provides technical reference information; it does not substitute for structural design.

Questions worth putting to your engineer if the requirement is still being assessed:

  • What are the design loads and member type? Columns, foundations and heavily loaded members generally point toward a higher grade than slabs or footings.
  • What is the exposure condition? Durability requirements linked to exposure can affect the water-cementitious ratio even at the same grade.
  • Is the concrete being pumped? Placement method feeds into the mix design's workability target.
  • What documentation does the project require? Testing and sampling frequency should be confirmed alongside the grade.

Share the application and project details with your enquiry and OM Group can discuss the requirement and quantities with you.

Workability, Pumping, Durability & Quality

What decides how it places, lasts and performs.

Workability & slump

Required workability should be specified according to placement method and project requirement — no universal slump figure is published here, and none is invented.

Pumpable concrete

Pumpability depends on aggregate grading, workability, mix design, admixtures and pumping distance. Not every mix is automatically pumpable — discuss the requirement directly.

Durability

Durability depends on mix design, water-cementitious ratio, materials, curing, exposure, cover, placement and workmanship. A higher M-grade number does not automatically mean more durable.

Quality control

Typical RMC practice includes raw-material checks, batching accuracy, fresh-concrete checks, sampling, cube testing and delivery documentation — stated as typical industry practice, not a specific certified process unless separately confirmed.

Compressive strength

Characteristic strength is the value below which no more than 5% of test results are expected to fall — a single cube result should never be read in isolation against the grade number.

Curing & site responsibility

RMC quality does not end at delivery. Final performance depends on placement, compaction, finishing and curing — all outside IS 4926's production-and-supply scope and outside OM Group's delivery responsibility.

How RMC Delivery Works

From requirement to discharge.

01Requirement Received
02Grade & Quantity Confirmed
03Delivery Scheduled
04Concrete Produced
05Transit Mixer Dispatched
06Site Arrival & Discharge
07Delivery Documentation

Site access, pour schedule, pump arrangement and discharge planning affect scheduling — no universal delivery time is promised. Prepare access, manpower, pump (if required), pour area and discharge location ahead of the scheduled delivery.

RMC Quantity & Price in Goa

Sold by volume; quoted against the requirement.

RMC is commercially supplied and invoiced by volume of fresh compacted concrete, in cubic metres (m³). Wastage allowance and pour sequencing should be discussed at ordering — no fixed truck capacity is published unless separately confirmed.

Price depends on grade, quantity, mix specification, delivery distance, pumping requirement and current material costs. No "starting from ₹X" figure is published without a genuine current rate — OM Group quotes against the specific requirement.

RMC Applications

Used across residential to infrastructure.

Foundations & footings

Foundation and footing pours, subject to the structural design's grade requirement.

Slabs, columns & beams

Standard structural elements across residential and commercial construction.

Residential construction

Villa, plot and residential RCC work, typically at ordinary or standard grades.

Commercial & industrial

Commercial towers and industrial structures, subject to project specification.

Infrastructure & large pours

Infrastructure work and larger continuous pours, coordinated to the pour schedule.

Retaining structures & rafts

Retaining structures and raft foundations, subject to structural design.

Every application above is subject to structural design and project specification — this page is a technical reference, not a design substitute.

Who Orders RMC from OM Group

Builders, contractors and project teams.

Builders & developers
Reliable supply and scheduling across residential and commercial projects
Civil & infrastructure contractors
Grade range and delivery coordination at project volumes
Structural contractors
Specification-led quotation and documentation
Industrial project contractors
Higher-grade and high-strength availability on request
Procurement teams
Single-source supply with coordinated dispatch across materials
Individual residential builders
Plain-language guidance and smaller-quantity orders
Why Source RMC from OM Group

Production, coordination and one relationship.

01

Own batching plants

RMC is produced at batching plants at Kundaim and Thivim, operated by Sabsol Qualitech Industries LLP under the OM Group brand — not resold from a third party.

02

Multi-grade supply

M20 through M45 supplied as standard, with high-strength grades such as M60 available on request against project confirmation.

03

Coordinated delivery

Delivery across North and South Goa on an owned transit-mixer fleet, coordinated with the same operation that dispatches OM Group's aggregate and sand.

04

One materials relationship

RMC sits alongside aggregates, sand and other OM Group materials — multi-material requirements can be quoted and coordinated together.

Product Specifications

Confirmed against the material supplied.

ProductReady Mix Concrete (RMC)
BrandOM Group
ProductionRMC batching plants, Kundaim & Thivim, operated by Sabsol Qualitech Industries LLP
Concrete gradeSelected per requirement — set by structural design
Applicable standard (production/supply)IS 4926:2003
Mix design referenceIS 10262:2019
Concrete code referenceIS 456:2000
Water-cementitious ratioProject-specific — set by mix design
Workability/slumpProject-specific — to be specified
Delivery methodTransit mixer
Testing requirementsAs applicable, to be specified
DocumentationDelivery ticket, available on request
Ready Mix Concrete material sample
Ordering RMC from OM Group

What to send for an accurate quote.

Rate depends on grade, quantity, mix specification and delivery location, so OM Group quotes against the specific requirement rather than publishing a list rate. Include the following:

GradeM20–M45, or the high-strength grade under discussion
QuantityVolume required, in cubic metres (m³)
Delivery locationProject site in Goa — determines logistics and affects scheduling
Pour date & timeOne-time supply or a phased schedule
ApplicationFoundation, slab, column, beam, or other
Pump requirementWhether the pour requires pump placement
Workability/slump requirementAs specified by your engineer or mix design
Specification requirementAny documentation or testing your engineer or client requires
ContactCompany name and the person handling procurement

Multiple grades can be ordered on one enquiry if a project needs more than one. If quantity is not yet fixed, share the application and approximate scope and OM Group can work from that.

Frequently Asked Questions

Common questions, answered directly.

Definition

What is Ready Mix Concrete?

Ready Mix Concrete (RMC) is concrete produced under controlled batching and mixing conditions and supplied to a construction site in a fresh state for placement, rather than mixed on site.

What is RMC?

RMC is the commonly used abbreviation for Ready Mix Concrete.

How is RMC made?

Raw materials are stored and proportioned at a batching plant to a specified mix design, mixed under quality control, then transported by transit mixer for site delivery and discharge.

What is the difference between RMC and site-mixed concrete?

RMC is batched under controlled plant conditions with batch-to-batch consistency managed at production; site-mixed concrete is prepared on site, with consistency depending on site practice and crew.

What does M20 mean?

M20 designates a concrete grade with a characteristic cube compressive strength of 20 MPa at 28 days.

Grades

What does M25 mean?

M25 designates a concrete grade with a characteristic cube compressive strength of 25 MPa at 28 days, classified as standard concrete requiring design mix.

What does M30 mean?

M30 designates a concrete grade with a characteristic cube compressive strength of 30 MPa at 28 days.

What does M40 mean?

M40 designates a concrete grade with a characteristic cube compressive strength of 40 MPa at 28 days, commonly considered for high-demand structural and infrastructure work.

What is M45 concrete?

M45 is a concrete grade with a characteristic cube compressive strength of 45 MPa, toward the upper end of the standard-concrete range under IS 456:2000, not classified as high-strength.

What is high-strength concrete?

High-strength concrete under IS 456:2000 begins at M60. M25 through M55 are classified as standard concrete, not high-strength, even though design mix is mandatory across that range.

What is M60 concrete?

M60 is a high-strength concrete grade with a characteristic cube compressive strength of 60 MPa, requiring performance-based mix evaluation rather than IS 456's standard design tables. OM Group supplies M60 on request.

What grades does OM Group supply?

M20 through M45 are supplied as standard. High-strength grades such as M60 are available on request, subject to project-specific confirmation. Share your requirement for current availability.

Technical

What is characteristic compressive strength?

Characteristic compressive strength is the strength below which no more than 5% of test results are expected to fall — the statistical basis for the grade designation.

What is cube strength?

Cube strength is the compressive strength measured from a standard 150mm cube specimen, typically tested at 28 days.

What is target mean strength?

Target mean strength is the mean strength a mix design aims for, set above the characteristic strength to statistically ensure the characteristic value is met across a batch of results.

What is IS 4926?

IS 4926:2003 is the Indian Standard governing the production and supply of Ready Mixed Concrete — batching, mixing, quality control and delivery documentation.

What is IS 10262?

IS 10262:2019 is the Indian Standard guideline for concrete mix proportioning, used to design the mix for a specified grade.

What is IS 456?

IS 456:2000 is the Indian Standard code of practice for plain and reinforced concrete, and is the source of the concrete grade table used to classify ordinary, standard and high-strength concrete.

What is the difference between nominal mix and design mix?

Nominal mix uses fixed proportions permitted only at M20 and below under IS 456:2000. Design mix is proportioned specifically to the project's materials and requirement, and is mandatory from M25 upward.

Mix Design

What is concrete mix design?

Concrete mix design is the process of proportioning cement, aggregates, water and admixtures to meet a project's strength, workability and durability requirements, referenced against IS 10262:2019.

What is water-cement ratio?

Water-cement ratio is the ratio of water to cementitious material in a mix, a primary driver of both strength and durability.

What factors determine mix design?

Characteristic strength, target mean strength, water-cementitious ratio, workability, aggregate grading, cementitious content, admixture use, durability requirement and exposure condition all feed into the mix design.

Can I get a specific mix recipe from OM Group?

No — mix proportions are project-specific and determined through the mix design process, not published as a generic recipe.

Quality

How is RMC quality controlled?

Typical RMC practice includes raw-material checks, batching accuracy control, fresh-concrete checks such as slump, sampling, cube testing and delivery documentation.

How is concrete tested?

Primarily through cube compressive-strength testing at specified ages, alongside fresh-concrete checks like slump at the point of delivery.

What is a cube test?

A cube test measures the compressive strength of a standard 150mm concrete cube specimen, typically at 28 days, used to verify the mix meets its characteristic strength.

Why shouldn't one cube result be judged in isolation?

Characteristic strength is a statistical value — up to 5% of results are expected to fall below it by design. A single result needs to be read against the full batch of test results, not treated as a pass/fail on its own.

What quality documentation is provided with delivery?

A delivery ticket is provided with each dispatch, with further documentation available on request, subject to what applies to the specific order.

Applications

Can RMC be used for foundations?

Yes, subject to the structural design's grade requirement for the specific foundation.

Can RMC be used for slabs, columns and beams?

Yes, across the standard grade range, subject to structural design.

Can RMC be used for residential construction?

Yes. Residential RCC commonly uses M20 or M25, subject to the project's structural design.

Can RMC be used for commercial and infrastructure work?

Yes, across the M20–M45 standard range and M60 on request, subject to project specification.

Which grade is used for foundations?

Commonly M20 to M30 depending on the structural design — this is not a prescription, and the actual requirement should come from your engineer.

Pumping

What is pumpable concrete?

Pumpable concrete is a mix with workability and grading suited to placement via concrete pump, depending on aggregate grading, admixtures and pumping distance.

Is every RMC mix pumpable?

No. Pumpability depends on the specific mix design and placement conditions — confirm the pump requirement before ordering so it can be reflected in the mix.

What should I confirm before requesting pumped concrete?

Pump distance, placement conditions and required workability — share these with your enquiry so the mix design can account for pumping.

Ordering

How do I order RMC?

Share grade, quantity, delivery location, pour date and time, and any specification requirement through the Request a Quote form, by phone or by WhatsApp.

What information should I provide when ordering?

Grade, quantity in cubic metres, delivery location, pour date/time, application, pump requirement, workability/slump requirement and any special specification.

How much RMC do I need?

Quantity is calculated from your project's volume requirement in cubic metres — share your drawings or pour volume and OM Group can work from that.

Is RMC sold by cubic metre?

Yes. RMC is commercially supplied and invoiced by volume of fresh compacted concrete, in cubic metres.

Can I order multiple grades on one project?

Yes. Multiple grades can be ordered on one enquiry if different elements of the project call for different grades.

Delivery

How is RMC delivered?

By transit mixer, scheduled against the confirmed pour date and site access, with delivery documentation provided on arrival.

What delivery method does OM Group use?

Transit mixer delivery, coordinated from the RMC batching plants at Kundaim and Thivim.

Does OM Group deliver across North and South Goa?

Yes, RMC is supplied across North Goa and South Goa.

What should I confirm about site access before delivery?

Access for the transit mixer, discharge point, pump arrangement if required, and pour sequencing — confirming these ahead of time avoids delays on delivery day.

Pricing

What is RMC price in Goa?

Rate depends on grade, quantity, mix specification, delivery distance and pumping requirement, so OM Group quotes against the specific requirement rather than publishing a list rate.

Does price vary by grade?

Yes. Higher grades generally carry a higher rate due to increased cementitious content and, at high-strength grades, additional mix-design and testing requirements.

How do I get current pricing?

Share grade, quantity, delivery location and pour schedule through the Request a Quote form, and OM Group will confirm current pricing against the requirement.

Goa

Where can I buy RMC in Goa?

OM Group supplies Ready Mix Concrete across North and South Goa, produced at its RMC batching plants at Kundaim and Thivim.

Does OM Group supply RMC in North Goa?

Yes. Both RMC batching plants — Kundaim and Thivim — are in North Goa, and OM Group delivers across the district.

Does OM Group supply RMC in South Goa?

Yes. RMC is delivered into South Goa from OM Group's operational bases, coordinated with its South Goa presence at Sancoale.

Procurement

What documentation comes with an RMC delivery?

A delivery ticket is provided with each dispatch. Further documentation is available on request, subject to what applies to the specific order.

What is a delivery ticket?

A delivery ticket is the record accompanying each RMC dispatch, typically confirming grade, quantity and dispatch details for the load delivered.

Who should I contact for a bulk RMC requirement?

Use the Request a Quote form with your quantity, grade and schedule, or contact OM Group directly by phone or WhatsApp — bulk and phased requirements are quoted directly against the project.

How do I request a quote?

Use the Request a Quote form on this page with grade, quantity, delivery location and pour schedule, or contact OM Group directly by phone or WhatsApp.

Related Products

OM Group supplies construction materials across Goa.

Request a Quote

Request Ready Mix Concrete for your project

Share the required grade, quantity, project location and delivery schedule, and OM Group will confirm current availability and pricing against the project requirement. Multiple materials can be quoted together.